I've had the boat for a week, still trying to figure out what is a "normal" level of water in the bilge. I know I've read about this subject on this forum before, I remember it being a bit contentious, with one camp saying there shouldn't be ANY water in the bilge, and another saying there will most always be water in the bilge. I have in-mast furling and our spring here in the Northeast has been quite soggy, so some rain water is to be expected. But I pumped out a half a bucket today!
Today I removed the pump and float and cleaned them both thoroughly. The float switch is working fine. One of the problems is the existing float switch requires quite a high water level to activate. This is partly due to the fact that it is sitting on a piece of 3/4" starboard block (see pics), so it is already fairly high off the bilge floor. One of my projects this summer is to possibly swap out the float switch. The PO provided me with the one that he intended to add (in my hand in the pic), I'm hoping that since it's lower profile maybe it will kick on at a lower water level. Wondering if anyone has come across this same issue, and if so what you can recommend?
See the attached pics, let me know ur thoughts!
Thanks (again)!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA




The switch may be one issue, but trust me on this: your pump will never be able to deliver a "dry" bilge, for at least 2 reasons. A) because if the switch was positioned and designed in a manner that would operate the pump until there was no water left, the pump would never turn off, and B) because once the pump goes off, there will be some backwash of water from the hose. There are some clever designed with sponges and vacuum pumps that might to it, but not a standard bilge pump.
Suggest you take a look at Tom Soko's article in the upgrade section here:
www.catalina36.org/members/technical/upgrades/adding-second-bilge-pump
Similar arrangements are described in Nigel Calder's "Boatowners Mechanical and Electical Manual" and Don Casey's "This Old Boat".
We've duplicated this on our boat, and while it doesn't get rid of all the water, the way the drain hose for the smaller ("primary") pump is plumbed with a loop (as illustrated in Soko's write-up) greatly cuts back on the backwash (and the smaller hose helps as well in limiting the amount of water that flows back). One still has the original (now "secondary") pump with a large hose size (and no loop) for when the perverbial excrement hits the fan and there's a lot of water to be pumped out in a hurry, activated by a second switch that is mounted somewhat higher. I find this redundency very comforting. In fect, we long ago made it a routine, as part of our "closing up the boat" checklist when we leave the boat for any length of time, to check the operation of both bilge pumps, and I've been surprised at the number of times I've discovered that one or the other pump was not working (a loose connection [it is a damp location], some crud wedged in the pump intake, a sticking switch, what have you).
Yes, there are members here who have acheived bone dry bilges -- I, sadly, am not numbered among them!
Matthew Chachère
s/v ¡Que Chévere!
(Formerly 1985 C36 MKI #466 tall rig fin keel M25)
2006 Catalina Morgan 440 #30.
Homeported in eastern Long Island, NY
Great stuff, as always. I'll take a look at those links. A loop makes sense, but what about a check valve? Do they make an in-line check valve to prevent the back wash? And do you think the float switch needs to be up on that block? Thanks again.
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
The collective wisdom I've read both online and in the two books I mentioned in my prior post (which, BTW, if you don't have them I highly recommend for your library) is that check valves are not a good idea on bilge pumps, because they can occassionally get stuck (which would not be good when you needed the pump to be operative!). This has been discussed before, and there are -- as always -- differing opinions: see, e.g. www.catalina36.org/forum/technical-discussion/bilge-pump-suck-and-fill . Mainesail's comment in that thread I dound to be particular compelling.
As to the mounting of the float switch, I'll offer a guess that a PO did that because the pump was cycling on and off too often. That was also discussed in the same thread above.
Matthew Chachère
s/v ¡Que Chévere!
(Formerly 1985 C36 MKI #466 tall rig fin keel M25)
2006 Catalina Morgan 440 #30.
Homeported in eastern Long Island, NY
I think about 1 inch, maybe a little more is normal. I did install a check valve that I bought at West Marine and haven’t had any issues.
Keep sending your questions to the forum - Lots of knowledge sharing and great people.
peter g
2000 C36, MK2, Hull. #1897
wonderful, wonderful, wonderful ! ! !. 5 th Catalina
I like the idea of creating a primary with a lower suction point, a smaller discharge hose and a loop. But, I am not confident enough to fill a hole in my new old boat and add a second discharge outlet. It's probably something better done on the hard anyway right? But I will copy that set up. Thx!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
Can't supply the confidence for you, but can supply some info: The hull (at least on our MK1) is not cored (so you don't need to go through the process of digging out core material around the hole and fillng with epoxy), and the thickness of the transom where the discharge mushroom fitting would be installed is actually suprisingly thin, so its not a difficult job, and certainly can be done while the boat is in the water (this is, after all, a discharge above the water line!).
But certainly a job you can wait to do until the off-season. You'll no doubt begin accumulating a list of things of changes/enhancements you'll want to do as you get more familiar with your new old boat, and hopefully a way of prioritizing them.
As Peter mentioned in his earlier comment, there is a wealth of info on this site; I encourage you to make liberal use of the search function, as you will often find an existing discussion or tech article that addresses your query. (Its one of the reasons why I think this is a far superior resource than the FB page, which I refuse to join or patronize for a variety of reasons).
Matthew Chachère
s/v ¡Que Chévere!
(Formerly 1985 C36 MKI #466 tall rig fin keel M25)
2006 Catalina Morgan 440 #30.
Homeported in eastern Long Island, NY
Mike,
I know this topic has been beaten to death in this thread and in others in the archives. Here are my two cents worth anyway. First, I'd confirm that no bilge pump arrangement will keep it completely dry. I am a proponent of the "dry bilge" school of thought. The only water that should find its way into Jubilee's bilge is from the roller furling mast, i.e. fresh rain water. I keep a small cheap wet/dry shop vac aboard. After rains, I just suck all the water out and pour it down the sink drain. If there is water in the bilge when there is no rain (which is most of the time here in San Francisco Bay), then I know that there is trouble somewhere else and I track it down. I use teflon packing material, so the packing gland is basically dripless. Jubilee's head shower has its own sump.
Al
Al Fricke
S/V Jubilee San Francisco Bay
Catalina 36' MkII #1867
Universal 35-B
AL, I guess I have to figure out where the water is coming from, maybe that's most important at this point. There always seems to be some water beneath the sink, not a ton, but it's wet there. The seacock doesn't seem to be leaking but I'll have another look. What are some of the typical sources of water, other than rain from the sail slot? I have a dripless pss, and that area is always dry, so I'm not concerned there, but I'm wondering about other points of intrusion. I'll have a good look with a flash light next time I'm aboard. Thx again. Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
Mike,
I agree with those that agree with the inevetible fact that there is no such thing as a "dry bilge"!!! My Admiral thinks I am nuts (and I may be!) but I am a stickler for keeping ours dry whenever possible. Some rain water will get in the mast and run down the inside there is no stopping that. I used to keep a small shop vac..... pain I T A digging it out and all that. Tried a hand pump... same PITA lining up outlet into bucket. One day I was cleaning out our aft cabin and came accros a Super Soaker water gun the PO left on the boat and I thought???? hmmm That is the best thing I have used so far! I take the bag out of my small trash can in the head, set it in the dryest end of the bilge and suck her dry! Even sucks up most of the hair (from the Admiral and her daughter!) and small particles that always find a way down there at the same time. Who'd a thunk!
Happy Sucking!
Mike and Nikki Willis
1996 C 36 #1570 "Slip Away"
MK II - Tall Rig - Winged Keel
Fremont, Ohio
Hey Mike, you are very right about the PITA it is to get out a bucket and then the hand pump (which sucks btw, you have to line the bucket up just right and some water always shoots out the connection where the hose joins the body of the pump, these things suck! [pun somewhat intended]). I love the idea of the super soaker, maybe easier than pulling out the hand pump that never works right. But...... there's more water entering the boat than from the sail slot. Need to find out where it's coming from.
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
Well asking for a laundry list of potential leak sites is another issues altogether, Mike! Here's my 4 cents worth overall:
List of my "Known Issues" that have been a source of leakage:
Note that I've had the vessel for over 4 years now. Still finding new sources! Once you've tracked down and fixed each one you have to dry all sides and compartments that slope into the bilge with a paper towel -- let things sit and then peer into each sloping area with a flashlight to look for drip lines, then track those paths back up to the source. HAPPY HUNTING!!!
Kevin Lenard
"Firefly"
'91 C-36 Mk. "1.5" Tall Rig, Fin Keel, Hull #1120, Universal M-35 original (not "A" or "B")
CBYC, Scarborough, Lake Ontario, Canada
Hey Kevin, wow, that is a comprehensive response! I am amazed at the amount of wisdom within this forum! Although the suggested scheme of adding the smaller pump and making it primary, with a lower profile switch, seems like a good way to go, drilling the hull for a discharge port out the transom is daunting to me (I'm not even comfortable screwing the mounting block to the floor of the bilge). So your suggestion of using check valves intrigues me. I'm a one man show and my job prevents me from getting on the boat each day. The boat is out on a mooring so having a trustworthy setup is of high importance. So far I know this: I want to add a second pump, with the pump pictured becoming secondary and a primary with a lower float switch being primary. Can I run the primary pump into the existing discharge tubing with a T fitting? Two pumps and one eventual discharge hose..... I'm betting there are some sea-manship reasons why this is a bad idea. But I'm with you Kevin, having two check valves seems like an acceptable level of risk? Curious to hear other points of view on this..... Thanks!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
NOTE: My apologies for the recommendation of the Whale SuperSub Smart 650. While I have one in our shower pan that works fine, the first one I had in the bilge stopped sensing the water level two years ago. It was sent back to Whale for testing, took TWO MONTHS (not clear what I was supposed to do for a bilge pump in the meantime) and was finally deemed faulty and replaced. The second one has now failed again -- the manual switch works fine and the pump works, it is the 'electro-static-magnetometer' or whatever they are using for the built-in sensor in the thin 'tail section' that no longer works. I cannot recommend it. Rule and other manufacturers make a low profile (although a bit longer) that might prove more reliable. I'm not replacing it just now, I'll rely on the main pump and I'll suck the bilge a bit drier with the Whale on manual regularly. Sad that this tech is not up to scratch.
Note further that the photo uploader seems to be rotating the pics 180 degrees.
Kevin Lenard
"Firefly"
'91 C-36 Mk. "1.5" Tall Rig, Fin Keel, Hull #1120, Universal M-35 original (not "A" or "B")
CBYC, Scarborough, Lake Ontario, Canada
The bilge pump blues continue....
I also have a 15 foot Boston Whaler. I dont spend a ton of time on it since we prefer to sail, so I rely heavily on it's bilge pump. When the RULE-MATE 1100 water sensor quit this spring, I replaced it. I agree with you Kevin, it is hard to trust Rule's water sensor technology. As attractive as having something solid-state in there (less apt to get gummed up), I think a float switch is probably the way to go. So I replaced the one on the Whaler with an Atwood 1100 that uses a mechanical float switch (the Rule 1100 was redesigned, go figure). Way more pump output than needed, but I was just trying to replace the pump that the PO had intalled. The last Rule lasted about 5 years, so to be fair, maybe that's a typical shelf life for an $85 pump.
Now, the Atwood is doing something weird! I installed it, wired it, and had it working just fine in AUTO when sitting on the back bench of the boat. But when my weight (150#) is OFF the boat, and I added a bucket of water, the pump ran continuously! I think the angle of the boat prevented the float switch from settling back to level. Yep, it killed my brand new start battery. I charged the battery back up and this time left it in off. I think the solution maybe to apply a slight shim to the back (foreward facing) side of the pump, and see if that helps. I also bought a one-way check valve to prevent the back flow. Curious to hear your thoughts on this one!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
In the Zodiac I have an Attwood 500 GPH auto float positioned in the lowest corner facing uphill as the 9.9 hp tilts to port when lifted. It works fine, but I've have had to replace it twice in the spring due to the standing water freezing and breaking the float mechanism.
Best thing I did was install a 6" x 12" solar charger on the top of the battery box that trickle charges the battery. I've had it on there for 3 years and even with the pump coming on several times a day (the 'guaranteed' no-leak fix I paid our local dinghy guy for two years ago has begun to fade...) the battery stays topped up for starting, no problem.
Kevin Lenard
"Firefly"
'91 C-36 Mk. "1.5" Tall Rig, Fin Keel, Hull #1120, Universal M-35 original (not "A" or "B")
CBYC, Scarborough, Lake Ontario, Canada
Hi,
You might consider to change the mechanical switch to an electronic one. During our almost 30 years with our C36 we have notice that when healing during long time, the classic switch sometimes connected the pump although no water was in, other times , got blocked with devries and did the same.
So we move to an electronic switch and voila! Perfect! The electronic can be regulated so starts operation only after continuisly detected water at certain level, and the most important, stops the pump after 15/20/25 sg no water is detected so normally no water is coming back.
Saying that, does not provide a totally dry bilge.
I fully agreed with Matheuw, you should only got water after rain, any else should be check. At a certain point, we had salt water coin in in, just when sailing, We got crazy but finally discover it was through the through hull sea cock that discharge water from the anchor well.
Sometimes we also had, sweet water and it was coming from the water tanks, when overfilled. The installed vent is not it enough if you are filling the tanks with a lot of water presion.
Just some thought,
Regards
Eladio Vallina
C-36 TR EUREKA II
Hull 1122 (1991)
Home port Barcelona (Spain).
Hereby, the electronic switch we use now.
Regards
Eladio Vallina
C-36 TR EUREKA II
Hull 1122 (1991)
Home port Barcelona (Spain).
Eladio, thanks very much for the suggestions. You have touched on my latest theory.... I think my stbd water tank is leaking. We were able to see some water weeping from the corner of the engine compartment closest to the tank. Earlier this spring I described a situation where, while in the hard, I had a hose running into the fill port for the stbd tank and went about my business, thinking I would hear and see it overfill. After some time, it was still going. I couldn't believe it was still taking water so I went down into the aft berth and found the tank had expanded so much that it pushed up on the board and mattress! Why didn't it overflow out the top fill port!!? Just garden hose pressure at the yard caused this? So I took the tank down to what looked like normal, via out the galley sink, and went on my way. Once in the water and under way, I started to see the excess bilge water. I think I have my answer. Other than tasting it, does anyone know of a test to determine if water is salt water or not? Anyone see a tank over pressurize like that before? Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
My centre water tank did the same. Turned out the vent hose that is on top of the tank got itself squished as the tank filled up. When nearing full capacity the tank expanded and as a result the vent hose got squeezed. So less venting, more expanding, more squeezing, more expanding, more squeezing, more.. Etc. After rerouting the vent hose and making sure it was routed up without dips to create a water lock, all is well.
Oh, and by the way, that caused a small leak at the threaded hose barb at the bottom of the tank and water in the bilge...
Henk Hiensch
Mar Y Sol
1984 Catalina 36
Hull# 379 Universal M25
Ladysmith, BC
Thanks very much. I'm currently out and enjoying a quiet morning, spent the night on the hook. I ensured we ran the stbd tank dry yesterday, so now we will see! Thanks again!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA
Super soaker works quite well. Discharge down kitchen sink, put a towel over cushions just in case...the admiral shows up & sees water spots.
peter g
2000 C36, MK2, Hull. #1897
wonderful, wonderful, wonderful ! ! !. 5 th Catalina
Add some lemon juice concentrate to suspect leaking tank. Then taste the drips to confirm....
peter g
2000 C36, MK2, Hull. #1897
wonderful, wonderful, wonderful ! ! !. 5 th Catalina
You could add food colouring to trace the leak, too, but to detail the 'burst tanks' issue, the squeezed vent hose could cause problems if it gets pinched while filling, but once the tank has been excessively pressured a few times, you are likely going to have problems at the several weak points: the outlet fitting, the inlet fitting, the large access fitting and the vent fitting. I had leaks on all four after attaching screwed-in fittings to the filler opening and connecting the shore water to them and turning it on full blast to speed up the filling process....yeah, I know. Live and learn... So none of those fitting are designed to handle full pressure, but they seal back up fairly well with the yellow 'extra strength/heavy duty' hot melt glue gun sticks as the gun will melt the plastic of the tank and fittings to acheive a complete 'weld'. Tried the Marine Goop with some success on the large top fitting. Access to the center aft tank outlet fitting was only possible by cutting open the plywood box at the port side, fore-end of the box.
The vent hoses of the two aft tanks are connected by a T connector and the portion from the center tank was lying on the inner hull below the top of the tank. I got in there with nylon zip ties and secured the hose against the underside of the bed platform and this seems to have helped to eliminate air locks, although the vents still tends to burp and hiccup a bit before the water eventually runs out of the vent indicating that one tank after the other has filled completely. I've had no more ruptureing issues since being more cautious, although one of my nephews did turn the water on full blast one time. Seems it might take repeated high pressure fillings to cause a problem.
Moral of the story, if you have removed the safety feature (not sure if it was planned?) of an open filling port by adding fittings, FILL SLOWLY (takes up to half an hour for the center tank).
Kevin Lenard
"Firefly"
'91 C-36 Mk. "1.5" Tall Rig, Fin Keel, Hull #1120, Universal M-35 original (not "A" or "B")
CBYC, Scarborough, Lake Ontario, Canada
I recently purchased the Dry Bilge System (www.drybilgesystem.com). It consists of a sensor which activates with about 3/16” of water, a control unit and a diaphragm pump. Once it senses water it turns on and runs for 10 seconds after the sensor reads dry. Pretty cool unit. I just did a temporary install without permanently mounting the pump or control. While testing it, it is powered off a jumpstart battery and the discharge is temporarily run to the sink. My testing was successful and it takes the bilge to dry.. We are expecting some rain in the next few days. When I get to the boat on Friday, if she is dry I will mount the control unit and pump next to the A/C, in the settee in front of the sink and run the discharge hose to the stern and install a new throughhull (or possibly tap into one of the existing discharges at existing throughhull. The electric hookup will be an easy run to the house batteries. Check out the website - he has a nice installation video. I spoke with him with a few questions - nice, knowledgeable and helpful guy. If anyone wants, let me know and I will post some photos when I get to the boat later in the week.
Roger Hare
Synchronicity, 2006 Cat 36 Mk II, #2283
Cayuga Lake, NY
Hey Roger, thanks for posting. I am definitely interested in this system. Please share photos when you get it installed!
Mike
Jackfish Girl, 1999, C36 MKII, Tall Rig, Wing Keel, In-mast furling, Monument Beach, Bourne, MA